Log In

Amara 8 Vacuum Autoclave

Aurora Side zoom

Hover

Aurora Open zoom

Hover

Aurora Front zoom

Hover

Aurora Side
Aurora Open
Aurora Front
Full Screen

Amara 8 Vacuum Autoclave

£1,680.00 (£1,400.00 + VAT)

Introducing our compact 8-litre benchtop autoclave, designed for optimal performance within Podiatry, Beauty, Tattoo and Piercing.

At Hollington, we’re committed to providing you with an autoclave that you can rely on.  We stand behind our products, and that’s why we offer an exclusive 2-year warranty.

New stock available around the end of August – start of September.  Get in touch if you would like to make a pre-order.

8 in stock

Elevate Your Sterilization Standards with the Hollington Medical Amara 8 B class autoclave.

 

Looking for a reliable sterilization solution for your practice or studio?  Look no further than the Hollington Medical Amara.  Designed to meet the stringent requirements of European standard EN13060, these autoclaves offer exceptional performance, safety, and convenience.

 

Unmatched Performance: Experience the ease of full automatic sterilization with pre-set programs tailored to your needs.  The Amara autoclave range excels in providing rapid and efficient sterilization cycles that meet the highest industry standards.


Intelligent Monitoring:
Stay in control with the intuitive LCD screen displaying essential information such as time, temperature, pressure, process alerts, and instrument conditions. The user-friendly interface makes operation simple and easy to navigate.


Advanced Safety Features:
Your safety is our priority.  Amara autoclaves come with a double safety protection system, preventing cycles from starting if the door isn’t locked correctly.  Pressure safety valves ensure pressure levels will never exceed the safe limit, and the system is designed to detect and identify issues, providing specific error codes for easy troubleshooting.


Efficient Datalogging Capabilities:
An internal printer is included along with USB port which allows easy transfer of sterilization data to PCs for electronic storage.  In addition to this, the Amara stores the last 20 cycles within its internal memory, with the option to print them out or transfer them electronically for future reference.

Features

  • Class B Autoclave
  • Quick cycle
  • B&D Test and Helix Test
  • Easy to maintain
  • Printer & USB
  • LCD display
  • Sterilising temperature 121°C/134°C
  • Wrapped or unwrapped


Warranty

At Hollington, we’re committed to providing you with an autoclave that you can rely on.  We stand behind our products, and that’s why we offer an exclusive 2-year warranty for every machine.


What Does Our Warranty Cover?


Product Reliability
: Your peace of mind is our priority.  Our warranty guarantees that your Amara autoclave will be free from defects in material and workmanship for a period of 2 years from the date of purchase.


Tech Support
: Have questions or need assistance?  Our friendly and knowledgeable customer support team is just a call or email away. We’re here to help you with any issues you may encounter during and after your warranty period.


Hassle-Free Repairs
: If your Amara autoclave experiences any issues covered by the warranty, we’ll make it right.  We’ll repair or replace your unit promptly, ensuring that you can continue your vital work without interruption.

Click here to read full warranty terms.

Please make sure to check the sizing of the autoclave to ensure the fit is suitable for you before ordering.  All specifications can be found on the ‘Technical Information’ tab.

Different delivery options available at checkout to suit your needs.

Size (L x W x H): 525 x 420 x 370mm

Tray Size (W x L): 130 x 265mm

Internal: 320 deep x 170mm Ø

Class: Class B Autoclave

Weight: 37kg

Volume: 8 Litres

Power: 2Kw 220V /50Hz

Sterilization Cycles

Program Temp / Pressure Steri. Time Suitable For Aurora 8 Aurora 12
Solid 134C 134C/210kPa 4min* Unwrapped solid instruments, unwrapped simple hollow instruments.

Cycle Time*

Load (Max)

17-22min

3.5kg

19-24min

4kg

Wrapped 134C 134C/210kPa 4min* Mixed load, single wrapped solid instruments, single wrapped hollow instruments. Cycle Time*

Load (Max)

22-40min

3.5kg

25-43min

4kg

Wrapped 121C 121C/110kPa 20min* Mixed load, single wrapped solid instruments, single wrapped hollow instruments. Cycle Time*

Load (Max)

38-50min

3.5kg

42-55min

4kg

Prion 134C 134C/210kPa 18min* Multiple wrapped instruments, textiles, danger of infection instruments. Cycle Time*

Load (Max)

 

35-55min

3.5kg

 

 

40-55min

4kg

*The cycle time is based on the load and with/without preheating.

*Drying time can be adjusted.

 

 

Additional information

Delivery & Installation

Couriered Delivery, Couriered Delivery prepaid first year service and PVI at discounted rate., Engineer Installation including product training + prepaid first year service and PVI at discounted rate., Engineer Installation including product training.

Palletised Delivery

We aim to deliver your autoclave within 3 to 5 business days from the date of your order, subject to product availability and your location. Please note that this timeframe may vary based on your specific circumstances.

Engineer Delivery and Installation

If you have requested engineer delivery and installation, please allow up to 7 to 10 business days from the date of your order for the complete installation by our expert technicians. Our team will contact you to schedule the installation at a time convenient for you.